RO Water Quality Requirements for Boilers:

 The water quality requirements for boilers are stringent because impurities in the water can cause various problems, such as scaling, corrosion, and reduced efficiency. Reverse Osmosis (RO) systems are commonly used to treat boiler feedwater to meet these quality standards. The specific RO requirements for a boiler depend on the type of boiler, operating pressure, and other operational factors.


### Key RO Water Quality Requirements for Boilers:

1. **Low Total Dissolved Solids (TDS)**:

   - High TDS in boiler feedwater can lead to scaling on the internal surfaces of the boiler. RO systems help reduce TDS levels significantly, which is crucial for preventing scale buildup and maintaining boiler efficiency.

   - **Typical TDS Range**: Ideally less than 10 ppm (parts per million) after RO treatment.


2. **Silica Removal**:

   - Silica can form hard, glass-like scales in high-pressure boilers. RO systems help in reducing silica levels in the feedwater.

   - **Silica Limit**: Below 20 ppm for low-pressure boilers, and for high-pressure boilers, much lower, often less than 1 ppm.


3. **Hardness Removal**:

   - Calcium and magnesium, which cause water hardness, can lead to scaling. RO systems remove a large percentage of hardness, protecting the boiler from scaling and improving efficiency.

   - **Typical Requirement**: Almost zero hardness, less than 1 ppm.


4. **Alkalinity Control**:

   - High alkalinity can cause boiler water to foam and carryover, leading to operational inefficiency. RO plants reduce the alkalinity by removing bicarbonates and carbonates.

   - **Alkalinity Limit**: Less than 10 ppm.


5. **Chloride Reduction**:

   - High chloride levels can cause corrosion in the boiler system. RO membranes are effective in reducing chloride levels.

   - **Chloride Limit**: Usually less than 20 ppm, depending on the boiler type.


6. **pH Control**:

   - The pH of the boiler feedwater should be neutral or slightly alkaline to prevent corrosion. While RO removes many contaminants, the post-RO water may need additional pH adjustment through chemical treatment.

   - **pH Range**: Typically 8.5-9.5, depending on the boiler type.


7. **Dissolved Oxygen Removal**:

   - RO systems do not effectively remove dissolved gases like oxygen, which can lead to corrosion. For this reason, de-aeration (thermal or chemical) is usually required after RO treatment to reduce dissolved oxygen levels.


### Boiler Types and RO Requirements:

1. **Low-Pressure Boilers** (below 300 psi):

   - RO water requirements are less stringent but still focus on reducing TDS, hardness, and alkalinity.

   - **TDS target**: 50-150 ppm.


2. **High-Pressure Boilers** (300 psi and above):

   - High-purity water is critical, and RO water must be of very high quality with almost no dissolved solids, silica, or hardness.

   - **TDS target**: Less than 10 ppm.


3. **Supercritical Boilers**:

   - These require ultra-pure water, as any impurities can cause significant scaling and damage due to high operating pressures and temperatures.

   - **TDS target**: Nearly 0 ppm, with further treatment through polishing processes like mixed-bed deionization.


### RO System Components for Boiler Feedwater:

- **Pre-treatment**: 

   - Before water enters the RO system, it must go through pre-treatment processes to remove large particles, chlorine (which can damage RO membranes), and other contaminants.

   - Common pre-treatment includes sediment filters, activated carbon filters, and softeners.

   

- **Post-treatment**: 

   - After RO, additional steps such as de-aeration (to remove dissolved oxygen) and chemical conditioning (pH adjustment) are often required for final feedwater preparation.


RO treatment is especially critical for high-pressure boilers where even small amounts of impurities can lead to significant damage, reducing boiler life and efficiency.